The CPT® Code 0384T refers to a specialized non-invasive procedure designed to assess heart rate and motion analysis over a period of 15 to 30 days. This procedure is particularly aimed at diagnosing nocturnal epilepsy seizure events. During the process, adhesive patches are affixed to the patient's body, which are then connected to sensors that continuously record electrocardiogram (ECG) data and monitor muscle activity. The recorded data captures vital information regarding the patient's heart rate and any muscle convulsions or vibrations that may occur during sleep, which are characteristic of tonic-clonic seizures. After the data collection period, the information is wirelessly transmitted to a computer where it is analyzed using sophisticated software. This software identifies specific cardiac patterns and muscle activity that may indicate seizure events. It is important to note that this code specifically covers the review and interpretation of the collected data, without including the actual data recording or scanning analysis, which is covered under other related codes. The distinction between the various codes, such as 0381T for up to 14 days and 0383T for 15-30 days, is crucial for accurate medical coding and billing practices.
© Copyright 2025 Coding Ahead. All rights reserved.
The procedure associated with CPT® Code 0384T is indicated for the assessment of nocturnal epilepsy seizure events. It is specifically utilized in cases where there is a need to monitor changes in heart rate and analyze motion data during sleep. This procedure is particularly relevant for patients who may exhibit symptoms suggestive of nocturnal seizures, allowing for a comprehensive evaluation of their cardiac and muscular activity during sleep periods.
The procedure for CPT® Code 0384T involves several key steps to ensure accurate data collection and analysis. First, adhesive patches are applied to the patient's body in specific locations to facilitate the recording of heart rate and muscle activity. These patches are equipped with sensors that capture electrocardiogram (ECG) data and monitor any motor activity indicative of seizures. Once the patches are securely in place, they begin recording data continuously over a period of 15 to 30 days. During this time, the sensors gather information on the patient's heart rate and any muscle convulsions or vibrations that may occur during sleep. After the data collection period concludes, the recorded information is wirelessly transmitted to a computer system. This data is then analyzed using specialized software designed to identify patterns in the cardiac activity and muscle movements that are characteristic of tonic-clonic seizures. The final step involves the review and interpretation of the analyzed data by a physician or qualified healthcare provider, who will assess the findings to determine the presence of nocturnal seizures.
After the completion of the procedure associated with CPT® Code 0384T, the patient may be advised on any necessary follow-up care or monitoring based on the results of the data analysis. The physician will provide guidance on interpreting the findings and may recommend further diagnostic testing or treatment options if nocturnal seizures are confirmed. It is essential for the patient to maintain communication with their healthcare provider regarding any ongoing symptoms or concerns following the procedure. Additionally, the physician may discuss the implications of the findings and potential next steps in managing the patient's condition.
Short Descr | EX H RATE SZ 15-30 DAY RI | Medium Descr | XTRNL HRT RATE EPI SEIZ 15 TO 30 DAYS R&I ONLY | Long Descr | External heart rate and 3-axis accelerometer data recording from 15 to 30 days to assess changes in heart rate and to monitor motion analysis for the purposes of diagnosing nocturnal epilepsy seizure events; review and interpretation only | Status Code | Carriers Price the Code | Global Days | XXX - Global Concept Does Not Apply | PC/TC Indicator (26, TC) | 0 - Physician Service Code | Multiple Procedures (51) | 0 - No payment adjustment rules for multiple procedures apply. | Bilateral Surgery (50) | 0 - 150% payment adjustment for bilateral procedures does NOT apply. | Physician Supervisions | 09 - Concept does not apply. | Assistant Surgeon (80, 82) | 0 - Payment restriction for assistants at surgery applies to this procedure... | Co-Surgeons (62) | 0 - Co-surgeons not permitted for this procedure. | Team Surgery (66) | 0 - Team surgeons not permitted for this procedure. | Diagnostic Imaging Family | 99 - Concept Does Not Apply | APC Status Indicator | Items and Services Not Billable to the MAC | Berenson-Eggers TOS (BETOS) | T2D - Other tests - other | MUE | Not applicable/unspecified. |
Date
|
Action
|
Notes
|
---|---|---|
2020-12-31 | Deleted | Code deleted, see 95999 |
2016-01-01 | Added | First appearance in codebook. |
2015-01-01 | Added | Added |