An interrogation device evaluation is a critical procedure performed in the context of cardiac resynchronization therapy (CRT). This evaluation is conducted in person and involves a comprehensive assessment of a wireless cardiac stimulator specifically designed for left ventricular pacing. During this procedure, the device is wirelessly connected to a computer system, allowing for the seamless transfer of stored data. The primary goal of this evaluation is to analyze the effectiveness of the current programmed parameters of the cardiac stimulator. The process begins with the connection of the device to the computer, followed by the recording of relevant data. Once the data is collected, it is downloaded into a specialized software program that meticulously evaluates the cardiac events that have triggered pacing, as well as the heart's response to these interventions. After the analysis is completed, the device is disconnected from the computer, and a qualified professional reviews the findings. A detailed report is generated based on this review, which may indicate whether any programming changes to the device are necessary. This thorough evaluation is essential for optimizing patient outcomes in those receiving CRT.
© Copyright 2025 Coding Ahead. All rights reserved.
The interrogation device evaluation is indicated for patients undergoing cardiac resynchronization therapy (CRT) who require assessment of the efficacy of their wireless cardiac stimulator for left ventricular pacing. This procedure is performed to ensure that the device is functioning optimally and to evaluate the heart's response to the pacing interventions.
The procedure for the interrogation device evaluation involves several key steps that ensure a thorough assessment of the cardiac stimulator's performance.
Post-procedure care following the interrogation device evaluation typically involves monitoring the patient for any immediate reactions to the evaluation. Patients may be advised to follow up with their healthcare provider to discuss the findings of the report and any recommended changes to their device programming. It is important for patients to understand the results of the evaluation and how it may impact their ongoing treatment plan. Additionally, any necessary adjustments to the device settings will be made based on the analysis to ensure optimal pacing and heart function.
Short Descr | INTERROG DEV EVAL WCS IP | Medium Descr | INTERROG DEV EVAL WRLS CAR STIMULATOR IN PERSON | Long Descr | Interrogation device evaluation (in person) with analysis, review and report, includes connection, recording, and disconnection per patient encounter, wireless cardiac stimulator for left ventricular pacing | Status Code | Carriers Price the Code | Global Days | XXX - Global Concept Does Not Apply | PC/TC Indicator (26, TC) | 1 - Diagnostic Tests for Radiology Services | Multiple Procedures (51) | 9 - Concept does not apply. | Bilateral Surgery (50) | 9 - Concept does not apply. | Physician Supervisions | 09 - Concept does not apply. | Assistant Surgeon (80, 82) | 9 - Concept does not apply. | Co-Surgeons (62) | 9 - Concept does not apply. | Team Surgery (66) | 9 - Concept does not apply. | Diagnostic Imaging Family | 99 - Concept Does Not Apply | APC Status Indicator | STV-Packaged Codes | Berenson-Eggers TOS (BETOS) | none | MUE | 1 |
26 | Professional component: certain procedures are a combination of a physician or other qualified health care professional component and a technical component. when the physician or other qualified health care professional component is reported separately, the service may be identified by adding modifier 26 to the usual procedure number. |