Coding Ahead
CasePilot
Medical Coding Assistant
Case2Code
Search and Code Lookup Tool
RedactPHI
HIPAA-Compliant PHI Redaction
DetectICD10CM
ICD-10-CM Code Detection
Log in Register free account
1 code page views remaining. Guest accounts are limited to 1 page view. Register free account to get 5 more views.
Log in Register free account

Official Description

Interrogation device evaluation (in person) of intracardiac ischemia monitoring system with analysis, review, and report

© Copyright 2025 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 0529T refers to the process of conducting an in-person interrogation device evaluation of an intracardiac ischemia monitoring system. This procedure is specifically performed when there is a device activation warning indicating a potential cardiac ischemia event. During this evaluation, the monitoring device may exhibit signs such as vibrations or activate an external alarm that can flash or beep, alerting the healthcare provider to the situation. The intracardiac ischemia monitoring system is designed to wirelessly connect to a computer, allowing for the seamless transfer of stored data. This data is then downloaded into a specialized software program that meticulously analyzes the cardiac event that triggered the warning. Following the analysis, appropriate interventions can be initiated based on the findings. The evaluation process includes a thorough review of the device's function in sensing ischemic events, as well as an examination of the interrogated data. Ultimately, a comprehensive written report is generated, summarizing the findings and any necessary actions to be taken.

© Copyright 2025 Coding Ahead. All rights reserved.

1. Indications

The interrogation device evaluation of an intracardiac ischemia monitoring system is indicated in specific scenarios where there is a concern for cardiac ischemia. The following conditions warrant this procedure:

  • Device Activation Warning This procedure is performed when the monitoring device activates, signaling a potential cardiac ischemia event, which may be indicated by alarms or vibrations from the device.

2. Procedure

The procedure for the interrogation device evaluation involves several critical steps to ensure accurate assessment and reporting of the cardiac event. The following steps outline the process:

  • Step 1: Device Connection The first step involves establishing a wireless connection between the intracardiac ischemia monitoring device and a computer. This connection is essential for downloading the stored data from the device, which contains information regarding the cardiac events that have occurred.
  • Step 2: Data Download Once the connection is established, the stored data is downloaded into a specialized software program. This software is designed to analyze the data related to the cardiac event that triggered the device's warning, providing insights into the nature and severity of the ischemic event.
  • Step 3: Analysis and Review After the data has been downloaded, a thorough analysis and review are conducted. This step involves evaluating the device's function in sensing ischemic events and examining the interrogated data to determine the appropriate clinical response.
  • Step 4: Report Generation Following the analysis, a comprehensive written report is generated. This report summarizes the findings from the evaluation, including any necessary interventions that may be required based on the data reviewed.

3. Post-Procedure

After the interrogation device evaluation is completed, the healthcare provider will review the findings with the patient and discuss any necessary follow-up actions. The report generated from the evaluation may guide further clinical decisions, including potential adjustments to the patient's treatment plan or additional monitoring requirements. It is essential to ensure that the patient understands the results and any implications for their cardiac health moving forward.

Short Descr INTERROG DEV EVAL IIMS IP
Medium Descr INTERROGATION DEVICE EVAL IIMS IN PERSON
Long Descr Interrogation device evaluation (in person) of intracardiac ischemia monitoring system with analysis, review, and report
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 1 - Diagnostic Tests for Radiology Services
Multiple Procedures (51) 9 - Concept does not apply.
Bilateral Surgery (50) 9 - Concept does not apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 9 - Concept does not apply.
Co-Surgeons (62) 9 - Concept does not apply.
Team Surgery (66) 9 - Concept does not apply.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator STV-Packaged Codes
Berenson-Eggers TOS (BETOS) none
MUE 1
Date
Action
Notes
2019-01-01 Added Added
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"