Official Description

Programming device evaluation (in-person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care professional, permanent implantable synchronized diaphragmatic stimulation system for augmentation of cardiac function

© Copyright 2025 American Medical Association. All rights reserved.

Common Language Description

A programming device evaluation is a critical procedure performed on an implantable synchronized diaphragmatic stimulation (SDS) system. This evaluation involves an in-person assessment where iterative adjustments are made to the implantable device. The primary goal is to test the device's function and select optimal permanent programmed values. During this process, a physician or other qualified healthcare professional conducts a thorough analysis and review, culminating in a written report that documents the findings and adjustments made. The patient undergoing this evaluation is typically connected to an electrocardiogram (ECG) monitor to continuously assess cardiac activity. A connection is established between the SDS device and specialized programming software, allowing for a comprehensive review of the device's current programming. Key aspects such as the SDS sensing function, leads, and battery status are evaluated to ensure proper operation. Additionally, the cardiac rhythm is monitored, and parameters such as generator voltage, lead impedance, and pulse width are meticulously reviewed, measured, and adjusted as necessary. This careful calibration of the device is essential for stimulating the diaphragm in sync with the cardiac cycle, which in turn modifies chest pressure to enhance the heart's filling and emptying processes, ultimately improving blood flow. After adjustments are made, the parameters are tested, and any required reprogramming of the device is performed based on the evaluation results. Finally, the patient receives instructions regarding any necessary follow-up services to ensure ongoing care and monitoring of the device's performance.

© Copyright 2025 Coding Ahead. All rights reserved.

1. Indications

The programming device evaluation for the implantable synchronized diaphragmatic stimulation (SDS) system is indicated for patients who require augmentation of cardiac function. This procedure is typically performed in cases where there is a need to enhance the heart's ability to fill and empty effectively, thereby improving overall blood flow. Specific indications may include patients with heart failure or other cardiac conditions that benefit from synchronized diaphragmatic stimulation.

  • Heart Failure Patients with heart failure may require this evaluation to optimize the functioning of the SDS system, which aids in improving cardiac output.
  • Cardiac Dysfunction Individuals with various forms of cardiac dysfunction may benefit from the adjustments made during the programming evaluation to enhance their cardiac function.

2. Procedure

The procedure for programming device evaluation involves several critical steps to ensure the optimal functioning of the implantable SDS system.

  • Step 1: Patient Preparation The patient is prepared for the evaluation by connecting them to an electrocardiogram (ECG) monitor. This allows for continuous monitoring of the cardiac rhythm throughout the procedure.
  • Step 2: Device Connection A connection is established between the SDS device and the programming software equipment. This connection is essential for accessing the device's programming data and making necessary adjustments.
  • Step 3: Data Review The healthcare professional reviews the current programming of the SDS device. This includes assessing the SDS sensing function, leads, and battery status to ensure that the device is functioning correctly.
  • Step 4: Parameter Assessment Key parameters such as generator voltage, lead impedance, and pulse width are measured and evaluated. This assessment is crucial for determining the effectiveness of the device in stimulating the diaphragm.
  • Step 5: Iterative Adjustments Based on the evaluations, iterative adjustments are made to the device settings. These adjustments are aimed at optimizing the stimulation of the diaphragm in sync with the cardiac cycle.
  • Step 6: Testing Adjusted Parameters After adjustments are made, the new parameters are tested to ensure they provide the desired effect on cardiac function. Any necessary reprogramming of the device is performed following careful evaluation.
  • Step 7: Documentation and Follow-Up The physician or qualified healthcare professional documents the findings and adjustments in a written report. The patient is then given instructions regarding any required follow-up services to monitor the device's performance.

3. Post-Procedure

Post-procedure care involves monitoring the patient for any immediate effects of the adjustments made to the SDS system. Patients are typically advised on the importance of follow-up appointments to ensure the device continues to function optimally. They may receive specific instructions regarding activity restrictions or signs and symptoms to watch for that could indicate a need for further evaluation. Continuous assessment of the device's performance is crucial for maintaining effective cardiac function and ensuring patient safety.

Short Descr PRGRMG DEV EVAL ISDSS IP
Medium Descr PROGRAMMING DEVICE EVALUATION IN PERSON ISDSS
Long Descr Programming device evaluation (in-person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care professional, permanent implantable synchronized diaphragmatic stimulation system for augmentation of cardiac function
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 1 - Diagnostic Tests for Radiology Services
Multiple Procedures (51) 6 - Special payment adjustment rules on the technical component (TC) of multiple diagnostic cardiovascular services apply...
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator STV-Packaged Codes
Berenson-Eggers TOS (BETOS) none
MUE 1
Date
Action
Notes
2022-01-01 Added Code added