Coding Ahead
CasePilot
Medical Coding Assistant
Case2Code
Search and Code Lookup Tool
RedactPHI
HIPAA-Compliant PHI Redaction
DetectICD10CM
ICD-10-CM Code Detection
Log in Register free account
1 code page views remaining. Guest accounts are limited to 1 page view. Register free account to get 5 more views.
Log in Register free account

Official Description

Remote autonomous algorithm-based recommendation system for insulin dose calculation and titration; provision of software, data collection, transmission, and storage, each 30 days

© Copyright 2025 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 0741T refers to a remote autonomous algorithm-based recommendation system specifically designed for insulin dose calculation and titration. This system is particularly beneficial for patients with poorly controlled diabetes who require multiple daily pen injections. The technology operates by utilizing an initial input of historical data, which includes time-stamped blood glucose readings and the amounts of insulin previously injected. This data is uploaded by the healthcare provider to the patient's smart device, allowing the system to generate real-time insulin dosage recommendations. The algorithm employs machine learning techniques to continuously assess the patient's glucose levels and predict the risk of hypoglycemia, thereby adjusting the recommended insulin doses automatically. The provision of this software, along with the necessary data collection, transmission, and storage, is billed for each 30-day period of use. It is important to note that the initial setup and patient education on how to utilize the system is reported separately under CPT® Code 0740T.

© Copyright 2025 Coding Ahead. All rights reserved.

1. Indications

The remote autonomous algorithm-based recommendation system for insulin dose calculation and titration is indicated for patients with poorly controlled diabetes who require multiple daily pen injections. This system is particularly useful for those who may struggle with managing their insulin dosages effectively due to fluctuating blood glucose levels.

  • Poorly Controlled Diabetes Patients who have difficulty maintaining stable blood glucose levels and require assistance in managing their insulin dosages.
  • Multiple Daily Pen Injections Individuals who need to administer insulin multiple times a day, making it essential to have precise dosage recommendations.

2. Procedure

The procedure for utilizing the remote autonomous algorithm-based recommendation system involves several key steps that ensure effective insulin dose calculation and titration.

  • Step 1: Initial Data Input The healthcare provider begins by collecting the patient's clinical history, which includes the latest time-stamped blood glucose readings and the amounts of insulin injected. This information is crucial for the algorithm to generate accurate dosage recommendations.
  • Step 2: Software Upload The provider uploads the algorithm-based software to the patient's smart device. This step is essential for enabling the system to function and provide real-time recommendations based on the patient's data.
  • Step 3: Algorithm-Based Recommendation Once the initial data is inputted, the system computes the first insulin dose recommendation. This recommendation is based on the historical data provided and is tailored to the patient's specific needs.
  • Step 4: Continuous Monitoring The system employs machine learning algorithms to continuously monitor the patient's glucose levels. It predicts the risk of hypoglycemia and adjusts the insulin dosage recommendations accordingly, ensuring that the patient receives the most appropriate dosage over time.

3. Post-Procedure

After the implementation of the remote autonomous algorithm-based recommendation system, the patient is expected to engage in regular monitoring of their blood glucose levels as recommended by their healthcare provider. The system will continue to collect and transmit data for a period of 30 days, during which the healthcare provider may review the data to make further adjustments if necessary. Patients should be educated on how to interpret the recommendations provided by the system and the importance of adhering to the suggested insulin dosages to maintain optimal blood glucose control.

Short Descr REM AUTON ALG NSLN DATA COLL
Medium Descr REM AUTON ALG NSLN DOS CAL SW DATA COLL TRANSMIS
Long Descr Remote autonomous algorithm-based recommendation system for insulin dose calculation and titration; provision of software, data collection, transmission, and storage, each 30 days
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 3 - Technical Component Only Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator Procedure or Service, Not Discounted when Multiple
Berenson-Eggers TOS (BETOS) none
MUE 1
Date
Action
Notes
2023-01-01 Added Code added.
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"