Coding Ahead
CasePilot
Medical Coding Assistant
Case2Code
Search and Code Lookup Tool
RedactPHI
HIPAA-Compliant PHI Redaction
DetectICD10CM
ICD-10-CM Code Detection
Log in Register free account
1 code page views remaining. Guest accounts are limited to 1 page view. Register free account to get 5 more views.
Log in Register free account

Official Description

Remote multi-day complex uroflowmetry (eg, calibrated electronic equipment); device supply with automated report generation, up to 10 days

© Copyright 2025 American Medical Association. All rights reserved.

Common Language Description

Remote multi-day complex uroflowmetry is a diagnostic procedure designed to assess urinary function over an extended period, specifically up to 10 days. This procedure is particularly beneficial for patients experiencing lower urinary tract symptoms, which may include a slow urine stream or difficulty initiating urination. The process involves the use of calibrated electronic equipment that captures various metrics related to urination. Uroflowmetry itself is a noninvasive test that provides valuable insights into urinary patterns by measuring the volume of urine voided, the speed at which urine is expelled, and the duration of the voiding process. The equipment can be integrated with a urinal or toilet, allowing for seamless data collection during normal urination. Prior to the test, patients receive education on how to use the device effectively, ensuring accurate data collection. The automated report generated by the equipment offers healthcare providers a comprehensive overview of the patient's urinary function, aiding in diagnosis and treatment planning.

© Copyright 2025 Coding Ahead. All rights reserved.

1. Indications

The remote multi-day complex uroflowmetry procedure is indicated for patients presenting with various lower urinary tract symptoms. These symptoms may include:

  • Slow Urine Stream Patients who experience a reduced flow rate during urination, which may indicate underlying urinary tract issues.
  • Trouble Urinating Individuals who have difficulty initiating urination or experience interruptions during the voiding process.

2. Procedure

The procedure for remote multi-day complex uroflowmetry involves several key steps to ensure accurate data collection and patient compliance. The initial step is the setup of the calibrated electronic equipment, which is essential for capturing the necessary urinary metrics. This setup includes fitting the device to a urinal or toilet, ensuring that it is properly positioned to record the flow of urine. Following the setup, healthcare providers educate the patient on how to use the equipment effectively. This education is crucial as it helps the patient understand the importance of consistent usage over the designated 10-day period. Once the patient is familiar with the device, they are instructed to use it during their normal urination routine. The equipment is activated before each voiding event, allowing it to measure and record the volume of urine, flow rate, and duration of urination. Throughout the 10 days, the device continuously collects data, which is later compiled into an automated report for the healthcare provider's review.

3. Post-Procedure

After the completion of the remote multi-day complex uroflowmetry procedure, the patient may resume their normal activities without any specific restrictions. The automated report generated by the device will be reviewed by the healthcare provider to assess the patient's urinary function. This report will provide insights into the patient's urinary patterns, which can assist in diagnosing any underlying conditions. Depending on the findings, further evaluation or treatment may be recommended. It is important for patients to follow up with their healthcare provider to discuss the results and any necessary next steps in their care plan.

Short Descr REM MLT DAY UROFLOW DEV SPLY
Medium Descr REM MULTI DAY CPLX UROFLOWMETRY DEV SPLY W/REPRT
Long Descr Remote multi-day complex uroflowmetry (eg, calibrated electronic equipment); device supply with automated report generation, up to 10 days
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 0 - Physician Service Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator STV-Packaged Codes
Berenson-Eggers TOS (BETOS) none
MUE 1
Date
Action
Notes
2024-01-01 Added Code Added.
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"