Official Description

Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular physiologic monitor system or subcutaneous cardiac rhythm monitor system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results

© Copyright 2025 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 93299 refers to the process of conducting one or more remote interrogation evaluations of an implantable cardiovascular physiologic monitor system or a subcutaneous cardiac rhythm monitor system. This procedure encompasses a comprehensive evaluation that can last up to 30 days. During this time, remote data acquisitions are performed, which involve the collection of data transmitted from the patient's device to a monitoring facility. The facility is responsible for registering the patient for remote interrogation and providing the necessary equipment, along with installation instructions and ongoing technical support to ensure proper setup. An interrogation schedule is established based on the physician's orders, guiding the technician in performing the device interrogation. The technician at the remote facility receives the transmitted data, reviews it meticulously, and compares it against the parameters set by the physician. This review includes an assessment of the device's functionality, such as the condition of leads and battery life. Any deviations from the established parameters, as well as alerts generated by the device, are identified and communicated to the physician. Additionally, any patient-reported symptoms or complaints are documented and relayed. The technician is also responsible for transferring all interrogated data and findings into the physician's database, culminating in the generation of a comprehensive report that outlines the evaluated parameters for the physician's review. This structured approach ensures that the physician has access to critical information necessary for ongoing patient management and care.

© Copyright 2025 Coding Ahead. All rights reserved.

1. Indications

The procedure described by CPT® Code 93299 is indicated for patients who require continuous monitoring of their cardiovascular health through an implantable cardiovascular physiologic monitor system or a subcutaneous cardiac rhythm monitor system. The following conditions may warrant the use of this remote interrogation evaluation:

  • Cardiac Arrhythmias Patients experiencing irregular heartbeats or arrhythmias may need ongoing monitoring to assess the frequency and nature of these events.
  • Heart Failure Individuals diagnosed with heart failure may require close observation of their cardiac function to manage their condition effectively.
  • Post-Operative Monitoring Patients who have undergone cardiac procedures may need to be monitored remotely to ensure proper recovery and device functionality.
  • Device Functionality Assessment Patients with implanted devices may need regular evaluations to ensure that the devices are functioning correctly and to identify any potential issues early.

2. Procedure

The procedure for CPT® Code 93299 involves several key steps that ensure comprehensive monitoring and evaluation of the patient's implantable cardiovascular device. The following procedural steps are performed:

  • Patient Registration The patient is registered at a monitoring facility for remote interrogation. This registration process includes providing the patient with the necessary equipment and installation instructions to facilitate the monitoring process.
  • Establishment of Interrogation Schedule Based on the physician's orders, an interrogation schedule is established. This schedule outlines the frequency and timing of the remote evaluations to ensure consistent monitoring.
  • Device Interrogation The technician performs the device interrogation according to the established schedule. This involves collecting data transmitted from the patient's device to the monitoring facility.
  • Data Review Upon receiving the transmitted data, the technician reviews it thoroughly. This review includes comparing the data against the parameters set by the physician to assess the patient's cardiac status.
  • Device Function Evaluation The technician evaluates the functionality of the device, including checking the leads and battery status. This step is crucial for identifying any potential issues that may affect the device's performance.
  • Communication of Findings Any variations from the established parameters, device alerts, and patient-reported symptoms are documented and communicated to the physician. This ensures that the physician is informed of any critical changes in the patient's condition.
  • Data Transfer and Reporting Finally, the technician transfers all interrogated data and findings to the physician's database. A comprehensive report is generated, summarizing the evaluated parameters for the physician's review and further action.

3. Post-Procedure

After the remote interrogation evaluations are completed, the technician ensures that all data is accurately documented and transferred to the physician's database. The physician will review the comprehensive report generated from the interrogation findings. Based on this review, the physician may decide on further management or treatment options for the patient. Continuous communication between the technician and the physician is essential to address any identified issues promptly. Additionally, the patient may receive follow-up instructions or recommendations based on the findings from the remote monitoring, ensuring ongoing care and support for their cardiovascular health.

Short Descr INTERROG EVAL ICPMS/SCRMS
Medium Descr REM INTERROG ICPMS/SCRMS <30 D TECH REVIEW
Long Descr Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular physiologic monitor system or subcutaneous cardiac rhythm monitor system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 3 - Technical Component Only Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 01 - Procedure must be performed under the general supervision of a physician.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator STV-Packaged Codes
Berenson-Eggers TOS (BETOS) I3C - Echography/ultrasonography - heart
MUE Not applicable/unspecified.
CCS Clinical Classification 203 - Electrographic cardiac monitoring