Official Description

Electronic analysis of implanted neurostimulator pulse generator/transmitter (eg, contact group[s], interleaving, amplitude, pulse width, frequency [Hz], on/off cycling, burst, magnet mode, dose lockout, patient selectable parameters, responsive neurostimulation, detection algorithms, closed loop parameters, and passive parameters) by physician or other qualified health care professional; with brain neurostimulator pulse generator/transmitter programming, first 15 minutes face-to-face time with physician or other qualified health care professional

© Copyright 2025 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 95983 pertains to the electronic analysis of an implanted neurostimulator pulse generator or transmitter, specifically focusing on brain neurostimulator systems. This procedure involves a comprehensive evaluation of various parameters that govern the functioning of the neurostimulator, which is crucial for treating neurological conditions. The implanted system typically consists of a pulse generator placed in a subcutaneous pocket, connected to electrode arrays that are inserted into targeted areas of the brain. These areas may include the brain's surface for cortical stimulation or deeper structures to address movement disorders such as Parkinson's disease, essential tremor, dystonia, and refractory epilepsy. The primary goal of this analysis is to ensure the device operates optimally, providing effective stimulation to injured brain regions or alleviating neuropathic pain disorders. During the electronic analysis, the physician or qualified healthcare professional assesses a range of parameters, including contact groups, interleaving, amplitude, pulse width, frequency (measured in Hertz), on/off cycling, burst mode, magnet mode, dose lockout, and patient-selectable parameters. Additionally, the analysis includes the evaluation of responsive neurostimulation, detection algorithms, closed-loop parameters, and passive parameters. The healthcare provider documents any logged events from the neurostimulator, battery status, electrode impedance, and the current settings programmed into the device. Furthermore, the programming aspect of the procedure involves checking stimulating parameters and electrode mapping to achieve optimal therapeutic stimulation. This is accomplished by systematically activating each electrode array in monopolar mode while monitoring neurological effects such as bradykinesia, twitching, rigidity, or facial pulling. After completing the electrode mapping, the healthcare professional determines and selects the final combination of parameters that will yield the best stimulation results while minimizing potential adverse effects. The code 95983 specifically reports the initial 15 minutes of face-to-face time spent by the physician or qualified healthcare professional on this analysis and programming, while code 95984 is used to report each additional 15 minutes of service provided.

© Copyright 2025 Coding Ahead. All rights reserved.

1. Indications

The electronic analysis and programming of an implanted brain neurostimulator pulse generator/transmitter, as described by CPT® Code 95983, is indicated for patients with various neurological conditions. These conditions may include:

  • Parkinson’s Disease A progressive neurological disorder characterized by tremors, rigidity, and bradykinesia, which may benefit from neurostimulation to alleviate symptoms.
  • Essential Tremor A movement disorder that causes involuntary shaking, often treated with neurostimulation to reduce tremor severity.
  • Dystonia A movement disorder resulting in involuntary muscle contractions, where neurostimulation can help manage symptoms.
  • Refractory Epilepsy A condition where seizures are not controlled by medication, and neurostimulation may provide an alternative treatment option.
  • Neuropathic Pain Disorders Chronic pain conditions resulting from nerve damage, which can be addressed through targeted neurostimulation.

2. Procedure

The procedure for CPT® Code 95983 involves several critical steps to ensure the effective analysis and programming of the implanted neurostimulator pulse generator/transmitter. Each step is essential for achieving optimal therapeutic outcomes.

  • Step 1: Initial Assessment The physician or qualified healthcare professional begins by reviewing the patient's medical history and any previous settings or adjustments made to the neurostimulator. This assessment helps in understanding the patient's current condition and the effectiveness of the existing stimulation parameters.
  • Step 2: Electronic Analysis The healthcare provider conducts a thorough electronic analysis of the neurostimulator. This includes evaluating various parameters such as contact groups, interleaving, amplitude, pulse width, frequency, on/off cycling, burst mode, magnet mode, dose lockout, and patient-selectable parameters. The analysis is crucial for identifying any issues with the device's performance and ensuring it is functioning optimally.
  • Step 3: Documentation During the analysis, the provider documents important data, including logged events from the neurostimulator, battery status, electrode impedance, and current programmed settings. This documentation is vital for tracking the device's performance over time and making informed decisions about adjustments.
  • Step 4: Electrode Mapping The next step involves programming the brain neurostimulator by checking stimulating parameters and performing electrode mapping. Each electrode array is activated systematically in monopolar mode, allowing the provider to observe the neurological effects, such as bradykinesia, twitching, rigidity, or facial pulling. This step is critical for determining the most effective stimulation settings.
  • Step 5: Parameter Adjustment After completing the electrode mapping, the healthcare professional selects the final combination of parameters that will provide optimal stimulation while minimizing adverse effects. This tailored approach ensures that the neurostimulator delivers the best possible therapeutic outcomes for the patient.

3. Post-Procedure

Following the electronic analysis and programming of the brain neurostimulator pulse generator/transmitter, the patient may be monitored for any immediate effects of the adjustments made. The healthcare provider will typically schedule follow-up appointments to assess the effectiveness of the new settings and make further adjustments if necessary. Patients may be advised on how to monitor their symptoms and report any changes or side effects experienced after the procedure. It is essential to ensure that the neurostimulator continues to function optimally and that the patient receives the intended therapeutic benefits. Regular follow-up and ongoing assessments are crucial for maintaining the effectiveness of the neurostimulator therapy.

Short Descr ALYS BRN NPGT PRGRMG 15 MIN
Medium Descr ELEC ALYS IMPLT BRN NPGT PRGRMG 1ST 15 MIN
Long Descr Electronic analysis of implanted neurostimulator pulse generator/transmitter (eg, contact group[s], interleaving, amplitude, pulse width, frequency [Hz], on/off cycling, burst, magnet mode, dose lockout, patient selectable parameters, responsive neurostimulation, detection algorithms, closed loop parameters, and passive parameters) by physician or other qualified health care professional; with brain neurostimulator pulse generator/transmitter programming, first 15 minutes face-to-face time with physician or other qualified health care professional
Status Code Active Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 0 - Physician Service Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator Procedure or Service, Not Discounted when Multiple
Type of Service (TOS) 1 - Medical Care
Berenson-Eggers TOS (BETOS) none
MUE 1

This is a primary code that can be used with these additional add-on codes.

95984 Telehealth Service (Medicare) Add-on Code Resequenced Code MPFS Status: Active Code APC N Electronic analysis of implanted neurostimulator pulse generator/transmitter (eg, contact group[s], interleaving, amplitude, pulse width, frequency [Hz], on/off cycling, burst, magnet mode, dose lockout, patient selectable parameters, responsive neurostimulation, detection algorithms, closed loop parameters, and passive parameters) by physician or other qualified health care professional; with brain neurostimulator pulse generator/transmitter programming, each additional 15 minutes face-to-face time with physician or other qualified health care professional (List separately in addition to code for primary procedure)
59 Distinct procedural service: under certain circumstances, it may be necessary to indicate that a procedure or service was distinct or independent from other non-e/m services performed on the same day. modifier 59 is used to identify procedures/services, other than e/m services, that are not normally reported together, but are appropriate under the circumstances. documentation must support a different session, different procedure or surgery, different site or organ system, separate incision/excision, separate lesion, or separate injury (or area of injury in extensive injuries) not ordinarily encountered or performed on the same day by the same individual. however, when another already established modifier is appropriate it should be used rather than modifier 59. only if no more descriptive modifier is available, and the use of modifier 59 best explains the circumstances, should modifier 59 be used. note: modifier 59 should not be appended to an e/m service. to report a separate and distinct e/m service with a non-e/m service performed on the same date, see modifier 25.
GC This service has been performed in part by a resident under the direction of a teaching physician
95 Synchronous telemedicine service rendered via a real-time interactive audio and video telecommunications system: synchronous telemedicine service is defined as a real-time interaction between a physician or other qualified health care professional and a patient who is located at a distant site from the physician or other qualified health care professional. the totality of the communication of information exchanged between the physician or other qualified health care professional and the patient during the course of the synchronous telemedicine service must be of an amount and nature that would be sufficient to meet the key components and/or requirements of the same service when rendered via a face-to-face interaction. modifier 95 may only be appended to the services listed in appendix p. appendix p is the list of cpt codes for services that are typically performed face-to-face, but may be rendered via a real-time (synchronous) interactive audio and video telecommunications system.
GW Service not related to the hospice patient's terminal condition
XU Unusual non-overlapping service, the use of a service that is distinct because it does not overlap usual components of the main service
CR Catastrophe/disaster related
Q1 Routine clinical service provided in a clinical research study that is in an approved clinical research study
GA Waiver of liability statement issued as required by payer policy, individual case
25 Significant, separately identifiable evaluation and management service by the same physician or other qualified health care professional on the same day of the procedure or other service: it may be necessary to indicate that on the day a procedure or service identified by a cpt code was performed, the patient's condition required a significant, separately identifiable e/m service above and beyond the other service provided or beyond the usual preoperative and postoperative care associated with the procedure that was performed. a significant, separately identifiable e/m service is defined or substantiated by documentation that satisfies the relevant criteria for the respective e/m service to be reported (see evaluation and management services guidelines for instructions on determining level of e/m service). the e/m service may be prompted by the symptom or condition for which the procedure and/or service was provided. as such, different diagnoses are not required for reporting of the e/m services on the same date. this circumstance may be reported by adding modifier 25 to the appropriate level of e/m service. note: this modifier is not used to report an e/m service that resulted in a decision to perform surgery. see modifier 57 for significant, separately identifiable non-e/m services, see modifier 59.
58 Staged or related procedure or service by the same physician or other qualified health care professional during the postoperative period: it may be necessary to indicate that the performance of a procedure or service during the postoperative period was: (a) planned or anticipated (staged); (b) more extensive than the original procedure; or (c) for therapy following a surgical procedure. this circumstance may be reported by adding modifier 58 to the staged or related procedure. note: for treatment of a problem that requires a return to the operating/procedure room (eg, unanticipated clinical condition), see modifier 78.
76 Repeat procedure or service by same physician or other qualified health care professional: it may be necessary to indicate that a procedure or service was repeated by the same physician or other qualified health care professional subsequent to the original procedure or service. this circumstance may be reported by adding modifier 76 to the repeated procedure or service. note: this modifier should not be appended to an e/m service.
77 Repeat procedure by another physician or other qualified health care professional: it may be necessary to indicate that a basic procedure or service was repeated by another physician or other qualified health care professional subsequent to the original procedure or service. this circumstance may be reported by adding modifier 77 to the repeated procedure or service. note: this modifier should not be appended to an e/m service.
79 Unrelated procedure or service by the same physician or other qualified health care professional during the postoperative period: the individual may need to indicate that the performance of a procedure or service during the postoperative period was unrelated to the original procedure. this circumstance may be reported by using modifier 79. (for repeat procedures on the same day, see modifier 76.)
AQ Physician providing a service in an unlisted health professional shortage area (hpsa)
FS Split (or shared) evaluation and management visit
GV Attending physician not employed or paid under arrangement by the patient's hospice provider
GZ Item or service expected to be denied as not reasonable and necessary
LT Left side (used to identify procedures performed on the left side of the body)
PN Non-excepted service provided at an off-campus, outpatient, provider-based department of a hospital
PO Excepted service provided at an off-campus, outpatient, provider-based department of a hospital
RT Right side (used to identify procedures performed on the right side of the body)
SA Nurse practitioner rendering service in collaboration with a physician
SG Ambulatory surgical center (asc) facility service
X2 Continuous/focused services: for reporting services by clinicians whose expertise is needed for the ongoing management of a chronic disease or a condition that needs to be managed and followed with no planned endpoint to the relationship; reporting clinician service examples include but are not limited to: a rheumatologist taking care of the patient's rheumatoid arthritis longitudinally but not providing general primary care services
X4 Episodic/focused services: for reporting services by clinicians who provide focused care on particular types of treatment limited to a defined period and circumstance; the patient has a problem, acute or chronic, that will be treated with surgery, radiation, or some other type of generally time-limited intervention; reporting clinician service examples include but are not limited to, the orthopedic surgeon performing a knee replacement and seeing the patient through the postoperative period
XE Separate encounter, a service that is distinct because it occurred during a separate encounter
XP Separate practitioner, a service that is distinct because it was performed by a different practitioner
XS Separate structure, a service that is distinct because it was performed on a separate organ/structure
Date
Action
Notes
2019-01-01 Added Added
Code
Description
Code
Description
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage