© Copyright 2025 American Medical Association. All rights reserved.
The procedure described by CPT® Code 0380T involves the use of computer-aided technology to analyze and animate time series retinal images, which is essential for monitoring the progression of various eye diseases. This innovative approach utilizes digital photography that is processed through specialized software, specifically designed to enhance the evaluation of retinal changes over time. The procedure requires two identical retinal images captured at different intervals, which are then aligned and registered by the software. This alignment creates a superimposed image that alternates rapidly, or 'flickers,' allowing for a dynamic visual representation of any changes that may have occurred between the two time points. The flickering effect is particularly beneficial as it accentuates even the most subtle alterations in the retinal structure, making it easier for healthcare professionals to detect disease progression. The application of this technology significantly reduces the time required for analysis while improving the detection rate of changes, thereby enhancing the accuracy of diagnostic evaluations. It also facilitates clinical consensus among healthcare providers, especially in cases where disease progression may be subtle and not easily identifiable through traditional methods. This procedure is applicable for monitoring a range of conditions, including but not limited to macular degeneration, retinal neoplasms, choroid disturbances, diabetic retinopathy, premature retinopathy, glaucoma, multiple sclerosis, and other central nervous system disorders. CPT® Code 0380T encompasses both unilateral and bilateral assessments of the posterior segment of the eye, and it includes the physician's interpretation of the findings along with a written report, ensuring comprehensive documentation of the patient's condition and the observed changes over time.
© Copyright 2025 Coding Ahead. All rights reserved.
The procedure associated with CPT® Code 0380T is indicated for the monitoring of disease progression in various ocular conditions. The following conditions are explicitly mentioned as suitable for this procedure:
The procedure for CPT® Code 0380T involves several key steps to ensure accurate monitoring of retinal changes. The first step is the acquisition of two identical retinal images taken at different time points. These images must be captured under similar conditions to ensure consistency. Once the images are obtained, they are uploaded into the computer software program, MatchFlicker. The software then aligns and registers the two images, creating a superimposed view that allows for direct comparison. Following the alignment, the software utilizes flickering technology to alternate between the two images rapidly. This flickering effect highlights any changes that have occurred over time, making even subtle differences in the retinal structure visible. The healthcare professional observes the flickering images to assess the degree of change, which is crucial for determining disease progression. After the analysis is complete, the physician interprets the findings and generates a written report. This report includes a detailed account of the observed changes, providing essential documentation for ongoing patient management and treatment planning. The entire process is designed to enhance the speed and accuracy of diagnostic evaluations, ultimately improving patient outcomes.
Post-procedure care following the application of CPT® Code 0380T typically involves the review of the written report generated by the physician. This report serves as a critical tool for ongoing patient management, allowing healthcare providers to make informed decisions regarding treatment options based on the documented findings. Patients may be scheduled for follow-up appointments to monitor their condition further, depending on the results of the analysis. Additionally, any necessary adjustments to treatment plans or further diagnostic evaluations may be discussed during these follow-up visits. It is essential for healthcare professionals to communicate the findings clearly to the patient and ensure that they understand the implications of the results for their ongoing care.
Short Descr | COMP ANIMAT RET IMAG SERIES | Medium Descr | COMP ANIMATION RETINA IMAGE TIME SERIES ANALYSIS | Long Descr | Computer-aided animation and analysis of time series retinal images for the monitoring of disease progression, unilateral or bilateral, with interpretation and report | Status Code | Carriers Price the Code | Global Days | XXX - Global Concept Does Not Apply | PC/TC Indicator (26, TC) | 0 - Physician Service Code | Multiple Procedures (51) | 0 - No payment adjustment rules for multiple procedures apply. | Bilateral Surgery (50) | 0 - 150% payment adjustment for bilateral procedures does NOT apply. | Physician Supervisions | 09 - Concept does not apply. | Assistant Surgeon (80, 82) | 0 - Payment restriction for assistants at surgery applies to this procedure... | Co-Surgeons (62) | 0 - Co-surgeons not permitted for this procedure. | Team Surgery (66) | 0 - Team surgeons not permitted for this procedure. | Diagnostic Imaging Family | 99 - Concept Does Not Apply | APC Status Indicator | STV-Packaged Codes | Berenson-Eggers TOS (BETOS) | M5C - Specialist - ophthalmology | MUE | Not applicable/unspecified. |
Date
|
Action
|
Notes
|
---|---|---|
2019-12-31 | Deleted | Code deleted, see 92499 |
2015-01-01 | Added | Added |
Get instant expert-level medical coding assistance.